Search
Close this search box.

Caddy Wood / Electric / Oil Furnace

SKU: PF01015

$5,799.00


You want to buy this product ?

Heating area1,000 – 2,500 Ft2
Size32 1/4″ W X 52 7/8″ D X 49″ H
Maximum log length22″
Average particulate emissions rate (1)0.654 lb/mmBTU (0.282 g/MJ)

Maximum recommended heating area by climate zone

The Cadillac of furnaces

Advanced combustion technology and state-of-the-art design have earned the Caddy furnace a reputation as the most efficient furnace ever produced by PSG-and with good reason! So how do you make a star product even better? With performance-enhancing electronics that take our flagship furnace to the next level.

Streamlined electronics and controls

The electronic components and controls of the redesigned Caddy have been reduced to just three components for greater ease of use and efficiency: 

  • An integrated PC board and RTD probe to control blower speeds and plenum temperatures, optimizing home comfort and furnace performance.
  • A blower assembly equipped with a prewired main power board for plug and play convenience upon installation.
  • A touchscreen LCD control module to make input and output control a breeze.

A unique heat exchanger system and outstanding performance

The secret behind the Caddy’s outstanding performance is its built-in heat exchanger system, which ensures that heat is transferred quickly and efficiently via the smoke ducts inside the furnace instead of being lost up the chimney. It uses up to 30% less firewood and reduces particulate emissions by as much as 80%. That’s great news for your heating bill-and the environment!

Alternate source of heat

With Caddy series furnaces, you’ll always have an alternate source of heat to ensure the comfort and safety of your family. The Caddy comes in four different configurations: wood-only, wood+electric combo, wood+oil combo, and wood add-on furnace.

NOTE: When installed as an add-on furnace, only a SERIES configuration is allowed in Canada.
The blower assembly is not required in a SERIES configuration.
Both PARALLEL and SERIES configurations are allowed in the USA.

APPLIANCE PERFORMANCE (2)

Fuel typeDry cordwood (16″ recommended)
Recommended heating area-ft² ()1,000 – 2,500
Overall firebox volume-ft³3.6
Maximum burn time ()15 h
Maximum input capacity (dry cordwood) (3)310,000 BTU
Overall heat output rate < (4)15,436 BTU/h (4.5 kW) to 49,638 BTU/h (14.5 kW)
Average overall efficiency (min. to max.) (5)76.70% (HHV) (6)82.90% (LHV) (7)
Delivered heat output rate (min. to max.) (8)12,635 BTU/h (3.7 kW) to 44,857 BTU/h (13.1 kW)
Average delivered efficiency (min. to max.) (9)62.70% (HHV) (6)68.30% (LHV) (7)
Optimum efficiency (10)84.90%
Average particulate emissions rate (1) (11)0.654 lb/mmBTU (0.282 g/MJ)
Average CO (12)11.18 lb/mmBTU (4.81 g/MJ)
Average electrical power consumption (13)432 W

(1) Based on delivered heat output.

(2) Values are as measured per CSA B415.1-10, except for the recommended heating area, firebox volume, maximum burn time and maximum input capacity. Performances based on a fuel load prescribed by the standard at 10 lb/ft³ and with a moisture content between 18% and 28%.

(3) Input value at 10 lb/ft³ fuel loading density and dry energy value of 8,600 BTU/lb.

(4) Overall : Radiated and delivered heat together at 10 lb/ft³ fuel loading density over one total burn cycle.

(5) Efficiency based on radiated and delivered heat when allowing cycling from high to low burn to simulate thermostat demand.

(6) Higher Heating Value of the fuel.

(7) Lower Heating Value of the fuel.

(8) Delivered: Remotely provided to other rooms through ducting at 10 lb/ft³ fuel loading density over one total burn cycle.

(9) Efficiency based on delivered heat when allowing cycling from high to low burn to simulate thermostat demand. LHV % is based on manufacturer’s estimation.

(10) Optimum overall efficiency at a specific burn rate (LHV).

(11) This appliance is officially tested and certified by an independent agency.

(12) Carbon monoxyde.

(13) Unless stated otherwise, measures were taken directly at the main power source and include all electrical components present in the appliance.

GENERAL FEATURES

High-efficiency certified applianceCSA B415.1-10
Maximum log length22″
Log positioningLoading over depth
Chimney diameter6″
Flue outlet diameter6″
Type of chimneyCAN/ULC S629, UL 103 HT (2100 °F)
Baffle typeC-Cast or equivalent
Shipping Weight576 lb (261 kg)
Door typeSingle, glass with cast iron frame
Glass typeCeramic glass
Glass surface – dimensions (Width X Height)12 1/2″ X 10 1/8″
Blower (hp / speed / CFM)1/3 / 4 / 1,900
Filter – dimensions (Width X Height X Depth)14″ X 25″ X 1″
Overall dimension (Height)49″
Overall dimension (Width)32 1/4″
Overall dimension (Depth)52 7/8″
Door opening – dimension (Height)10″
Door opening – dimension (Width)13 3/4″
Firebox – dimension (Height)16″
Firebox – dimension (Width)17″
Firebox – dimension (Depth)22 5/8″
Steel thickness – body3/16″
Steel thickness – top1/4″
Easy-to-access ash drawerYes
Air return plenum – dimension (Depth or Height)15 3/4″
Air return plenum – dimension (Width)24 3/4″
Hot air plenum – dimension (Depth or Height)28 5/8″
Hot air plenum – dimension (Width)24 1/2″
Wood Add-on – location of the connection with the existing furnaceRight or left
Burner – standardBeckett AFG
Burner – other brand approvedRiello, Aero
Burner – locationRight or left
Burner – recommended connector pipe diameter (Wood-oil)7″
Burner – recommended exhaust pipe diameter5″
Burner – location of exhaust pipeRight or left
Burner – capacity at input #190,000 BTU (26.4 kW)
Burner – orifice at input #10,55 X 60° W (Beckett)
Burner – pump pressure at input #1140 psi
Burner – efficiency85 % (Beckett)
Burner – recommended clearance for maintenance24″
Electric element – locationRight or left
Electric element – recommended (maximum output)18 kW
Electric element – recommended clearance for maintenance29″
Electric element – other optional (maximum output)15 kW or 20 kW
Canadian Standard (emissions)CSA B415.1-10
USA standard (safety)UL 391, UL 1995, UL 727
Canadian standard (safety)CSA B366.1, CSA C22.2 no 236, CAN/CSA B140.4
Tested and listed as per applicable standardsBy an accredited laboratory (CAN/USA)
WarrantyLimited lifetime
Minimum clearances to combustibles*
(Data expressed in inches. 1 inch = 25.4 mm)
 CanadaUnited-States
Clearance – back wall24″24″
Clearance – ducts<6’=6″ ; >6’=1″<6’=6″ ; >6’=1″
Clearance – recommended for maintenance on option side24″24″
Clearance – front48″48″
Clearance – side wall6″6″
Clearance – opposite side wall24″24″
Clearance – top (measured from the platform on which the appliance is installed)**72″72″

* The information given on the certification label affixed to the appliance always overrides the information published in any other media (owner’s manual, catalogues, flyers, magazines and/or web sites).

** Some appliances have been tested with a low ceiling. Before setting up your unit, refer to the installation manual.

This product interest you ? Contact-us

Contact us and a representative will be happy to answer your questions