Home > Shop > Stoves & Fireplaces > Pellet Stoves & Fireplaces > Pellets Stoves > EUROMAX PELLET HEATER
The Euromax is as close as you can get to a pellet furnace. It is equipped with a 125-pound hopper. Its state-of-the-art LCD control lets you choose between various settings with the touch of a finger. The bottom feed technology used inside the Euromax minimizes burn pot maintenance while allowing a more complete and efficient combustion.
Affordable, intelligent, stylish and clean…This is heating in the 21st Century.
Government incentives may apply to this product.
*Any installation must be done according to the data and drawings detailed in the owner’s manual.
Fuel type : | Pellet (Premium grade or better) (2) | |
Recommended heating area-ft² : (*) | 1,000 – 2,800 | |
Hopper capacity : | 125 lb (57 kg) | |
Maximum burn time : () | 104 h | |
Maximum heat input rate : (3) | 70,500 BTU/h (20.6 kW) | |
Overall heat output rate < : (4) | 8,300 BTU/h (2.4 kW) to 36,700 BTU/h (10.8 kW) | |
Average overall efficiency : (5) | 68.8 % (HHV) (6) | 74.4 % (LHV) (7) |
Optimum efficiency : (8) (9) | 79.9 % | |
Burn rate : | 1.2 – 8.2 lb/h | |
Average particulate emissions rate : (10) | 2.45 g/h | |
Average CO : (11) | 117.2 g/h | |
Average electrical power consumption-ignition cycle : (12) | 3.7A (360 W) | |
Average electrical power consumption for continuous operation : (12) | 2.15 – 2.9A (258 – 348W) |
(1) Values are as measured per CSA B415.1-10, except for the recommended heating area, hopper capacity, maximum burn time and maximum heat input rate. Results may vary depending on pellet quality, density, length, and diameter.
(2) Grades of pellet fuel are determined by organizations such as Pellet Fuels Institute (PFI), ENplus and CANplus.
(*) Recommended heating area and maximum burn time may vary subject to location in home, chimney draft, heat loss factors, climate, fuel type, feed rate, fuel level, and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature considering that the space configuration and the presence of heat distribution systems have a significant impact in making heat circulation optimum.
(3) Based on the maximum burn-rate and a dry energy value of pellet at 8,600 BTU/lb.
(4) As measured per CSA B415.1-10 stack loss method.
(5) Efficiency based on radiated and delivered heat when allowing cycling from high to low burn to simulate thermostat demand. LHV % is based on manufacturer’s estimation.
(6) Higher Heating Value of the fuel.
(7) Lower Heating Value of the fuel.
(8) Performances based on a fuel load prescribed by the standard at 7 lb/ft³ and with a moisture content between 19% and 25%.
(9) Optimum overall efficiency at a specific burn rate (LHV).
(10) This appliance is officially tested and certified by an independent agency.
(11) Carbon monoxyde.
(12) Unless stated otherwise, measures were taken directly at the main power source and include all electrical components present in the appliance.
Number of intensity levels | 6 |
Combustion technology | Bottom-feed |
Thermostatic or manual mode | Yes |
High-efficiency certified appliance | CSA B415.1-10 |
Electronic igniter | Yes |
Chimney diameter | 4″ |
Flue outlet diameter | 4″ |
Type of chimney | ULC/ORD-C441, CAN/ULC S609, UL 641 (TYPE L) |
Baffle type | Stainless steel |
Approved for a mobile home installation | Yes, with fresh air intake |
Shipping Weight | 467 lb (212 kg) |
Door type | Single, glass with cast iron frame |
Glass type | Ceramic glass |
Glass surface – dimensions (Width X Height) | 14″ X 8 1/2″ |
Glass air-wash system | Yes |
Premium quality blower included (CFM) | 500 |
Noise level at 6 feet | 53 dBa (+/- 3 dBa) – 59 dBa (+/- 3 dBa) |
Overall dimension (Height) | 41 1/4″ |
Overall dimension (Width) | 24 5/8″ |
Overall dimension (Depth) | 37″ |
Voltage and frequency | 120VAC – 60 Hz |
AC Current | 2.15A/120VAC – 3.7A/120VAC |
Main control board fuses | 7.5A-250V |
Canadian Standard (emissions) | CSA B415.1-10 |
USA standard (safety) | UL 1482, ASTM E1509 |
Canadian standard (safety) | ULC S627 |
Tested and listed as per applicable standards | By an accredited laboratory (CAN/USA) |
Warranty | Limited lifetime |
Minimum clearances to combustibles* (Data expressed in inches. 1 inch = 25.4 mm) | ||
Canada | United-States | |
Clearance – back wall | 3″ | 3″ |
Clearance – corner | 3″ | 3″ |
Clearance – side wall | 6″ | 6″ |
Clearance – top (measured from the platform on which the appliance is installed)** | 72″ | 72″ |
* The information given on the certification label affixed to the appliance always overrides the information published in any other media (owner’s manual, catalogues, flyers, magazines and/or web sites). | ||
** Some appliances have been tested with a low ceiling. Before setting up your unit, refer to the installation manual. |
Contact us and a representative will be happy to answer your questions