fbpx
Search
Close this search box.

SOLUTION 1.7 WOOD STOVE

SKU: SBI EB00055

Starting at $2,299.00


You want to buy this product ?

Combine refinement and performance at all times, for personalized use and an ever-more accessible heating experience with the all-new Solution 1.7.

Medium-sized, the unit features sleek, elegant lines: side panels with delicate engraved grooves, an arched cast iron door, a slightly curved top, a sturdy ash pan, and a customizable base with six choices of legs or a pedestal. Give meaning to your interior, give yourself the cozy nest you dream of!

APPROVED FOR THE ISLAND OF MONTREAL

Government incentives may apply to this product.

*Any installation must be done according to the data and drawings detailed in the owner’s manual.

APPLIANCE PERFORMANCE (1)

Fuel type :Dry cordwood (16″ recommended)
Recommended heating area-ft² : (*)500 – 1,800
Overall firebox volume-ft³ :1.86
EPA loading volume-ft³ :1.44
Maximum burn time : (*)7 h
Maximum heat output-dry cordwood : (2)65,000 BTU/h (19 kW)
Overall heat output rate < : (2) (3)9,800 BTU/h (2.87 kW) to 52,200 BTU/h (15.3 kW)
Average overall efficiency (dry cordwood) : (3)68 % (HHV) (4)73 % (LHV) (5)
Optimum overall efficiency : (6) (7)76 %
Optimum heat transfer efficiency : (8)75 %
Average particulate emissions rate : (9)2.4 g/h
Average CO : (10)103 g/h

(1) Values are as measured per test method, except for the recommended heating area, firebox volume, maximum burn time and maximum heat output.

(2) The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft³ and 20 lb/ft³ and reloading intervals ranging from 60 to 120 minutes. Other performances are based on a fuel load prescribed by the standard without any reloading between start and finish. The specified loading density varies between 7 lb/ft³ and 12 lb/ft³. The moisture content is between 19% and 25%.

(3) As measured per CSA B415.1-10 stack loss method.

(4) Higher Heating Value of the fuel.

(5) Lower Heating Value of the fuel.

(6) Performances based on a fuel load prescribed by the standard at 7 lb/ft³ and with a moisture content between 19% and 25%.

(7) Optimum overall efficiency at a specific burn rate (LHV).

(8) The optimum heat transfer efficiency is for the low burn rate (using HHV) and represents the appliance’s ability to convert the energy contained in the wood logs into energy transferred to the room in the form of heat and does not take into account the chemical losses during combustion.

(9) This appliance is officially tested and certified by an independent agency.

(10) Carbon monoxyde.

GENERAL FEATURES

Combustion technologyNon-catalytic
High-efficiency certified applianceYes, EPA 2020 approved
Maximum log length18″
Log positioningLoading over width
Chimney diameter6″
Flue outlet diameter6″
Type of chimneyCAN/ULC S629, UL 103 HT (2100 °F)
Minimum chimney height (feet)15′
Baffle typeC-Cast or equivalent
Approved for an alcove installationYes
Approved for a mobile home installationYes, with fresh air intake
Shipping Weight341 lb (155 kg)
Door typeSingle, glass with cast iron frame
Glass typeCeramic glass
Glass surface – dimensions (Width X Height)15 7/8″ x 9 7/8″
Glass air-wash systemYes
Overall dimension (Height)30 1/8″
Overall dimension (Width)28″
Overall dimension (Depth)23 5/8″
Door opening – dimension (Height)8 3/4″
Door opening – dimension (Width)17 1/4″
Firebox – dimension (Height)11 7/8″
Firebox – dimension (Width)19 5/8″
Firebox – dimension (Depth)13 1/2″
Firebox lined with refractory bricks for better heat distributionYes
Stainless-steel secondary-air system improving gas combustionYes
Steel thickness – body3/16″
Steel thickness – top3/8″
USA standard (emissions)EPA
Canadian Standard (emissions)CSA B415.1-10
USA standard (safety)UL 1482, UL 737
Canadian standard (safety)ULC S627
Tested and listed as per applicable standardsBy an accredited laboratory (CAN/USA)
WarrantyLimited lifetime
Minimum clearances to combustibles*
(Data expressed in inches. 1 inch = 25.4 mm)
CanadaUnited-States
Single wall pipeDouble wall pipeSingle wall pipeDouble wall pipe
Clearance – back wall14 1/2″7 1/2″13″7 1/2″
Clearance – corner12″12″12″12″
Clearance – side wall10″10″10″10″
Clearance – top (measured from the platform on which the appliance is installed)**84″84″84″84″
Clearance – minimum floor protection in front of the appliance18″16″

* The information given on the certification label affixed to the appliance always overrides the information published in any other media (owner’s manual, catalogues, flyers, magazines and/or web sites).

** Some appliances have been tested with a low ceiling. Before setting up your unit, refer to the installation manual.

This product interest you ? Contact-us

Contact us and a representative will be happy to answer your questions